Technical Parameters
project | parameter |
Measuring range | 100Pa~3000kPa |
Ambient temperature | -40℃~+85℃ |
Medium temperature | -40℃~+120℃ |
stability | 0.15% URL/15 years |
Output | 4~20mA HART |
weight | 3.3kg |
Accuracy | |
A | Basic error ±0.05% (not applicable to ranges A0, A7, B) |
B | Basic error ±0.075% |
C | Basic error ±0.1% |
Range | |
A | 0-100Pa~1kPa Rated working pressure 0.2MPa |
B | 0-200Pa~6kPa/(0~2~60mbar) |
C | 0-400Pa~40kPa/(0~20~400mbar) |
D | 0-2.5kPa~250kPa/(0~25~2500mbar) |
F | 0-30kPa~3MPa/(0~0.3~30bar) |
The central sensing unit uses high-precision silicon technology, accurate to ±0.05% (up to ±0.025%)
Double overload protection diaphragm design, single-phase overpressure can reach 32MPa
Static pressure error can reach ±0.05% / within 10MPa
Temperature performance is within ±0.04% / 10K, and the temperature effect is small
Range ratio adjustment 100:1, wider adaptability
EMC complies with GB/T 18268.1-2010